Cleaning, Decontamination and Disinfection is about a fifth of the CRCST exam. Cleaning is the most important step in reprocessing: if an instrument isn’t clean, it can’t be reliably disinfected or sterilized. Here’s what to know, followed by free practice questions. Questions follow HSPA’s content outline and AAMI standards; at work, each device’s instructions for use (IFU) and your department’s policies come first.

Point of use

  • Remove gross soil from instruments right after the procedure.
  • Keep instruments moist (for example with an enzymatic spray, foam or a damp towel, as your facility directs) so soil doesn’t dry on.
  • Open hinged instruments and separate sharps and delicate items.
  • Transport in closed, leak-proof, labeled (biohazard) containers or carts.

The decontamination area

  • Wear full PPE: fluid-resistant gown, heavy-duty gloves, face protection (mask and goggles or a face shield), hair cover and shoe covers.
  • The area has negative air pressure relative to surrounding areas, so contaminated air doesn’t flow out.
  • Traffic flows one way: dirty to clean.

Manual cleaning

  • Follow the detergent manufacturer’s dilution, temperature and contact time.
  • Clean instruments under the surface of the water to avoid splashing and aerosols.
  • Use brushes of the right size for each lumen, and brush lumens thoroughly.
  • Rinse well to remove detergent residue.

Mechanical cleaning

Equipment How it works Notes
Ultrasonic cleaner Sound waves create tiny bubbles that implode (cavitation) and remove fine soil Removes soil from hard-to-reach areas; follow the IFU for which items can go in
Washer-disinfector Washes, rinses, thermally disinfects and dries in cycles Load so water and detergent reach all surfaces

Free practice questions

  1. Why must instruments be kept moist after use until they're cleaned?
  2. What air pressure does the decontamination area have compared with surrounding areas?
  3. Why are instruments cleaned under the surface of the water during manual cleaning?
  4. How does an ultrasonic cleaner remove soil?
  5. How should contaminated instruments be transported to decontamination?
  6. When using an enzymatic detergent, what should be followed?

Pass the CRCST exam on your first try

  • All 207 questions on decontamination, disinfection, instruments, packaging, sterilization, storage, patient care equipment and professional skills
  • An explanation for every answer, with the AAMI standard, CDC guideline or OSHA rule behind it
  • Unlimited full 125-question practice exams, with each domain in its real share
Start practicing

CRCSTTests

Full access

Free for 7 days

Then $29 per month

Due today$0.00
  • All 207 questions on decontamination, disinfection, instruments, packaging, sterilization, storage, patient care equipment and professional skills
  • An explanation for every answer, with the AAMI standard, CDC guideline or OSHA rule behind it
  • Unlimited full 125-question practice exams, with each domain in its real share
  • Practice exams for each domain

Cancel anytime before and you will not be charged.

Secured by Stripe